Split Type Elevator Load Weighing Device RHP-X-OMS-560 Elevator Load Weigher
Place of Origin | NINGBO CITY, CHINA |
---|---|
Brand Name | SUMT, ANT |
Model Number | OMS-560-RHP-E-3T |
Minimum Order Quantity | MOQ:20sets |
Price | USD80-140/PC |
Packaging Details | Box+carton, 25SETS/Carton, 14kg/carton, carton size: 45x34x36.5cm |
Delivery Time | 3-20 working days depending on the quantity |
Payment Terms | T/T, Western Union, MoneyGram,Paypal |
Supply Ability | 5000-1000pcs/month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xMaterial | Stainless Steel | Rated Load | Any Weight |
---|---|---|---|
Voltage | DC19-29V | Cable Length | 3m, 4 Blank Wire |
Installation Location | Ifts' Crosshead Beam /frame Structure | Display Mode | Weight/percentage |
Structure | Split Type | Alarm Relay Output | 5(overload,full Load,empty Load, Optical,acousti |
High Light | Split Type Elevator Load Weighing Device,Elevator Load Weighing Device RHP-X-OMS-560,RHP-X-OMS-560 Elevator Load Weigher |
SUMMIT Split type elevator load measuring system RHP-X-OMS-560 mounting on car frame crosshead beam strain link tesion load weighing device
Installation loacation: Between wire rope hitch plates:OMS-560-RHP-X
Description:
The load weighing system consists of one crossbeam sensor RHP-X and a weighing control unit OMS-560, and the sensors RHP-X is mounted to load bearing members of the car or shaft assembly that are stressed with bending loads during operation.
The bending is recorded by the crossbeam sensor and sent to the control unit OMS-560 for evaluation, and we have a range of weighing control units(OMS-820, OMS-520, OMS-370C and so on), which is matched with the beam sensor RHP-X.
Features:
- Cost efficient and precise method
- Very easy to install
- Static load at fixing point(under the plate of wire rope attachment)
- Suitable for the new installations and modernization project
- Menu-guided operation
- 5 relays output overload,full,half empty,optical, audio output
- DIN Rail or on flat surface mounting with screws
- IP-65 rated plastic box.
- Integrated software to correct weight increases due to compensating chain.
- Display load as well as percentage
- Protecting important data from being disturbed by password
- Automatic correction of zero drift, makes the equipment in optimum stage
- Self-learning function, regulating high floor additional weight error
- Control equipment swap entirely,self-diagnosis and alarming
- Self-learning operating conducted by any fixed load
Control Unit:OMS-560 | |||
Operation Voltage | AC/DC16-48V | Sensor operation voltage | DC5V |
Nominal power | 4W | Signal Hold Voltage | AC/DC12-45V |
Input Channel (Load Cell ) | 2 | Measuring precision | 0.1% |
Relay Number |
5(overload,full,half empty,optical, audio output) |
Operation temperature | -45degree-+85degree |
Contact Load | 8A250VAC,5A 250VAC,5A 30VDC | Size | 90x84x58mm |
Display Type | 4 digits 0.56 inch LED | Weight | 265g |
Display mode | Weight/percentage | Shell material | ABS |
Model: | RHP-X | ||
Rated Load |
Undefined, works with bending steel frame |
Output Resistance | 352M+/-2 ohm |
Rated Output | 2.0+-0.02%mv/v | Connection type | 4 blank wire |
Total error | +/-0.5% F.S | Input Resistance | 380+/-10 ohm |
Repeatability | +/-0.5% F.S. | Construction material | Stainless Alloy steel |
Creep 30min | +/-0.05% F.S/30min | Protection Class | IP68 |
Zero Balance | +/-1% F.S. | Insulation impedance | ≥5000Ω |
T C SPAN | +/-0.02% F.S./10 degree Celsius | Cable length | 3m(blank) |
Operation temperature range | -30 to 70 degree Celsius | Excitation | DC 5-12V |
Wiring Diagram:
4-core blank wire :
Installation location&Size:
Instruction:
The purpose of the SUMMIT Load Weighing system is to measure the load in the elevator and pro-vide usable information about the load to the elevator controller. This information is used forpre-torquing and for dispatching decisions, e.g. light load anti-nuisance, heavy load and over-load.
The system usually consists of a sensor or group of sensors mounted on the elevator’s some position such as clamping on wire rope, or under cabin, under the wire rope plate installation and a control unit. The sensor(s) provide a signal to the control unit directly related to the amount of load in the cab. The load weighing control accepts this signal and provides usable data to the elevator controller in the form of an analog signal and discrete relay contacts.